Part Number Hot Search : 
5HFP100 SMD1113 BD718 PM4381 0066AA9 SR410 AD7711SQ 91SAM
Product Description
Full Text Search
 

To Download 26YY50202 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  grayhill, inc. ? 561 hillgrove avenue ? lagrange, illinois 60525-5997 ? usa ? phone: 708-354-1040 ? fax: 708-354-2820 ? www.grayhill.com optical and mechanical encoders mechanical encoders series 26 pull to turn i solated positions bcd or gray code shaft & panel seal dimensions in inches (and millimeters) unless specifed otherwise, all tolerances are .015 ( 0,38) specifi cations electrical ratings r ated: 25,000 cycles with logic compatible loads. make and break 200 ma. contact resistance: 500 milliohms maximum (less than 100 milliohms initially) insulation resistance: 1000 megohms minimum (10,000 megohms initially) dielectric strength: 250 vac minimum materials and finishes panel seal: silicone rubber shaft seal: fluorosilicone mounting nut: brass, tin/zinc-plated lockwasher: steel, tin/zinc-plated detent balls: carbon steel, nickel-plated detent spring: pretinned music wire detent rotor: thermoplastic shaft, stop arm and pins: stainless steel bushing: zamak 3 zinc alloy, tin plate switch base : diallyl phthalate printed circuit board: nema grade fr-4 terminals: brass, gold over nickel plate contacts : copper alloy, gold over nickel additional characteristics shaft vertical travel: .050 +/- .010 pull force required: 1.75 +/- .75 lbs. rotational torque: 7 to 13oz-in vibration r esistance: 10 to 55 hz at 0.060" double amplitude; no damage and no contact openings per mil-std-202, method 201a shock r esistance: passes medium requirement per mil-dtl-3786 stop strength: 5 in-lbs minimum mounting strength: 15 in-lbs max r elative humidity: 90-95% at 40 o c for 240 hours (mil-std-202 method 103, test condition a) grayhill part number and date code marked on label. customer part number marked on request. options i solated positions the grayhill system for isolating positions lets you choose the positions to be isolated. grayhill inserts isolation posts next to the positions to be isolated. consider a continuous rotation switch with a 22.5 angle of throw. the terminals are listed here from 1 through 16 with a space between each to indicate where isolation posts might be inserted. 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 to isolate position 1 and position 2 from all other positions and from each other, indicate isolation posts as shown here: 16 p 1 p 2 p 3 4 5 6 7 8 9 10 11 12 13 14 15 16 to isolate just position 1, describe like this: 16 p 1 p 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 to isolate positions 1 and 2 from all other positions, but not from each other, do this: 16 p 1 2 p 3 4 5 6 7 8 9 10 11 12 13 14 15 16 fixed stop switches the switch may have continuous rotation, or specified to limit the rotation. when a 1-pole switch has less than the maximum number of positions, consider also the stop system. following is the arrangement for a 6 position switch with the position 1 isolated. stop 1p2 3 4 5 6 stop the word stop indicates the conventional switch stops, which limit rotation to positions 1 through 6. to isolate position 1 we insert only one isolation postCbetween terminals 1 and 2. the stop system already prevents rotation beyond terminal 1. due to the vast number of possible confgurations of isolated positions and stop arrangements, each series 26 pull-to-turn mechanical encoder will be assigned a unique part number. for example, part 26YY50202 is a 16 position gray code switch with positions 1 and 16 isolated and a stop at each extreme. contact grayhill or an authorized representative to create a part number and obtain pricing. ordering infor mation code and tr uth tabl e *dot indicates terminal tied to common. description an isolated position is one that cannot be reached by normal rotation. this version of the series 26 mechanical encoder requires that the operator pull-to-turn in order to reach the isolated position. to rotate out of the isolated position, the operator must pull-to-turn again. use isolated positions to protect a switch position from indiscriminate rotation. this feature is typically used for positions such as calibrate, off and/or stand-by. code position bcd output* gray output* 1 2 4 8 1 2 4 8 1 0 2 1 3 2 4 3 5 4 6 5 7 6 8 7 9 8 10 9 11 10 12 11 13 12 14 13 15 14 16 15 switch position


▲Up To Search▲   

 
Price & Availability of 26YY50202

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X